Siphonic and Gravity for LEED Platinum Miesian Plaza

Miesian Plaza

  • Project
    Miesian Plaza
  • Location
    Dublin
  • Consulting Engineers
    ARUP
  • M&E Contractor
    Winthrop
  • Architect
    RKD
  • Technology
    Siphonic & Gravity System
  • Scope
    Design, manufacture, installation

Originally designed by Scott Tallon Walker in the 1960’s, Miesian Plaza underwent extensive redevelopment to provide Grade A office accommodation in line with best international practice and to the highest environmental standards. The completed buildings were awarded LEED Platinum v4 accreditation.

Design

Capcon Engineering completed a detailed design to allow for the integration of a modern drainage system into a historic building while contributing towards LEED Platinum Accreditation. This included a detailed co-ordination process between Capcon Engineering and the design team made possible using the Valsir Rainplus technology.

Construction

Following the design stage Capcon Engineering pre-fabricated HDPE lengths to suit the siphonic calculations which were supplied and installed on site by our experienced crews. The works were completed on a phase basis to suit the main construction programme. Following installation all works were tested and warrantied with all Ancillary certification for the works provided.

We were able to provide a one stop solution from design to sign off while also providing a warranty for the works as all calculations are completed in house.